Concrete C16-C20-C25, for exposed reinforced concrete structures

Concrete Cement (t) Aggregate
(m3)
Water
(m3)
Plasticizer
(kg)
Retarder
(kg)
Strength Dmax Consistency 250 bspc 60 350 bspc 60
C16 16 Kx 0.354 - 1.147 0.19 1.8 -
KKxx 0.323 - 1.146 0.18 - 4.8
24 KKxx 0.313 - 1.135 0.17 - 4.7
32 KKxx 0.303 - 1.124 0.16 - 4.5
C20 16 KKx 0.333 - 1.208 0.16 1.7 -
KKxx 0.374 - 1.105 0.19 - 5.6
24 Kx 0.394 - 1.078 0.2 2.0 -
KKxx 0.359 - 1.097 0.18 - 5.3
32 Kx 0.384 - 1.069 0.19 1.9 -
KKxx 0.343 - 1.09 0.17 - 5.2
C25 16 KKx 0.374 - 1.178 0.165 1.9 -
KKxx 0.424 - 1.163 0.2 - 6.4
24 Kx 0.48 - 1.018 0.21 2.4 -
KKxx 0.409 - 1.056 0.19 - 6.1
32 Kx 0.455 - 1.026 0.195 1.8 -
KKxx 0.394 - 1.05 0.18 - 5.9
x for solid plain surface
xx for grained (antislip) surface
Plasticizer agent e.g.: Plastol BF
Retarding admixture e.g.: Keterdol F